Rx61-22 Instructions (v6.0.2)


PRODUCT: Rx61


Outputs

Channels

Channels

Tx22

1. DEFAULT SETUP

Item

Setting Details
Purpose:

Rx61-2 Train with Tx22 transmitter

Red wire positive (+)
Black wire negative (-)

Battery 3-16v
Observe polarities
Integrated BEC

4v Suitable to power 1 small servo
H1 output
Brown wires

Motor
Speed knob (Ch1)

Integrated forward/reverse ESC for brushed motors
Center off
P1 output

Servo
Bind button (Ch5)

Slow-motion servo for coupling
Integrated 4v power supply for servo (BEC)
Press bind button to open coupling
Release bind button to close coupling

P2 output

Front Light
Direction switch (Ch3)

Led needs current limiting resistor
Direction switch 'up' for on (center off)
P3 output

Rear Light
Direction switch (Ch3)

Led needs current limiting resistor
Direction switch 'down' for on (center off)
P5 output
On/Off
Bind button (Ch5)
Item being switched needs current limiting resistor
ON while button pressed, OFF when released

P4 output
Light (Ch4)
Not used with Tx22
P6 output
Light (Ch6)
Not used with Tx22
P7 output
Light (Ch7)
Not used with Tx22

Selecta

Enabled

Up to 12 locos can be associated with Selecta switch on Tx22
The selector switch position is memorised during binding.
Rx 'holds' motor setting when deselected (suitable for continuous loop)
Led 2-flash if loco is not currently selected

Arming:

Enabled Motor control knob to center position (off)

LVC Enabled LVC=Low Voltage Cutoff
Led 5-flash if triggered
Stop and charge battery

Inactivity Sleep Enabled After 1 hour
Switch off and on to restart


2. EXAMPLE CONNECTIONS:


Motor (H1 output)

Servo (P1)

Led (P7)

'P' outputs are 3v when on and 0v when off. Led's need resistors to limit current to 20mA but high brightness led's allow a lower current (eg: 2-5mA). Google will reveal how to select resistor values but 220-470ohms will be safe starting values.

The 4v BEC output is suitable to power a small servo when the Rx is powered with a higher voltage. When the Rx is powered with 1S lipo, it would be more normal to power a servo direct from the lipo



3. BINDING

Bind once (not necessary if Rx was supplied pre-bound):
1. Switch Rx on and wait ~20s until led flickers fast.
2. Choose the Selecta switch position for this loco.
3. Switch Tx on in bind mode.
4. Rx led should flash slowly; wait for it to go solid.
Change distance between Tx/Rx if binding does not work.




4. LED:
Led On = perfect reception (real-time indicator).
1 flash = Scanning (~2sec between flashes; no signal or not bound if never stops).
2 flash = Loco not selected.
5 flash = LVC/Brownout (voltage went too low; check battery/motor load).

5. FAILSAFE:
The motor output is not active on startup and while scanning for a signal.
The motor output 'holds' last known settings on short signal losses (<1sec) and then slows to a stop over 3 seconds.

6. OTHER:
This receiver has other features that are not described.
These are changed using a technique called 'programming':

Version v6.0.2
v6.0.1