Rx62 - Programming v611
|
1. PROGRAMMING APPROACH:
Settings in the Rx can be changed using a joystick Tx or a suitable programing device (Tx20, Prog1, Prog3, Prog4). All use the structure in the table below. One output or feature (ie: one row in the table) is programmed at a time. Each change usually comprises a 5 number sequence. Numbers from the first two columns usually select the output and the other three change its characteristics. [KEYWORDS] provide links to more detailed descriptions of each feature.
Outputs are usually controlled by channels. Each knob or switch on the Tx controls one channel. Outputs like motor and servos are used in a proportional manner. This allows very fine control, usually 512 or 1024 step resolution. Channels controlling outputs that switch on/off usually divide the channel into 2 or 3 positions: low, center and high. Menu 12 and 13 allows one channel to have up to 12 positions to control more things.
2. PROGRAMMING OPTIONS:
Level 1 |
Level 2 |
Level 3 |
Level 4 |
Level 5 |
Information |
|
|||||
Menu 1 Motor |
Output number: | Output type: | Channel number: | Other: | |
1 | 1 = H1 |
1 = Center off (1ch, half each way) [M-TYPE-1] |
1-18 = Channel |
Forward and Reverse with one control (-100% < 0 > +100%) (eg: 1,1,1,1 = Menu1, H1, Center off, Ch1) |
|
1 | 1 = H1 |
2 = Low off (2ch: speed + direction) [M-TYPE-2] |
1-18 = Channel Throttle |
1-18 = Channel Direction |
One control for Throttle (0 ~ 100%) Second control for Direction (eg: 1,1,2,1,3 = H1, Low off, Ch1 Throttle, Ch3 Direction) |
1 | 1 = H1 |
3 = Not used |
|||
|
|||||
1 | 1 = H1 |
4 = Start power (0-100%) [M-MIN] |
0-10 = Tens (x10) (0-flash = 0) |
0-9 = Ones (x1) (0-flash = 0) |
Minimum power level (0% for full power range) (eg: 1,1,4,2,5 = H1, Min power, 25%) |
1 | 1 = H1 |
5 = Max power (0-100%) [M-MAX] |
0-10 = Tens (x10) (0-flash = 0) |
0-9 = Ones (x1) (0-flash = 0) |
Maximum power level (100% for full power range) |
|
|||||
1 | 1 = H1 |
6 = Motor Reverse [M-REV] |
1 = Normal 2 = Reversed 3 * Normal (no toggle) 4 = Reversed (no toggle) |
Options 1/2 allow motor direction to be toggled if throttle is at max at startup Options 3/4 do not |
|
1 |
1 = H1 |
7 = PWM Frequency [M-PWM] |
1 = 16 kHz 2 = 8 kHz 3 = 2 kHz 4 = 500 Hz 5 = 120 Hz |
(eg: 1,1,7,1 = H1, 16kHz) |
|
1 |
1 = H1 |
8 = Soft start / Inertia [M-SOFT] |
1 = immediate 2 = 0.25s 3 = 0.5s 4 = 1s 5 = 2s 6 = 4s 7 = 8s |
Speed of throttle change (0-100% durations): (eg: 1,1,8,4 = H1, 1s inertia) (1=immediate/no inertia from v611-2) |
|
|
|||||
Menu 2 Servo, Brake, Reverse, Indicator |
Pad number: | Output type: | Channel number: | Other: | |
2 |
1-5 = P1-P5 |
1 = Servo (normal) [SERVO-1] |
1-18 = Channel |
1 = normal speed 2-6 = slow motion |
Servo on any pad Full throw from full stick movement (eg: 2,4,1,5,1 = P4, Normal servo operation with Ch5) (eg: 2,4,1,5,6 = P4, Slowest servo movement with Ch5) |
2 |
1-5 = P1-P5 |
2 = Servo (offset) [SERVO-2] |
1-18 = Channel |
1 = low/right stick 2 = high/left stick |
Servo on any pad Full throw from half stick movement |
2 |
1-5 = P1-P5 |
3 = Servo (toggle) [SERVO-3] |
1-18 = Channel |
1 = 60% throw 2 = 70% throw 3 = 80% throw 4 = 90% throw 5 = 100% throw 6 = 110% throw 7 = 120% throw |
Servo toggles each time Channel is low This allows operation with a pushbutton |
|
|||||
2 | 1 = 1st Ch |
4 = Servo (mixed) 2-channel mix [SERVO-4a] |
1-18 = Primary Ch |
1 = 25% mix 2 = 50% mix 3 = 75% mix 4 = 100% mix |
P1/P2 used as a pair Primary channel and Mix% |
2 | 2 = 2nd Ch |
4 = Servo (mixed) 2-channel mix [SERVO-4b] |
1-18 = Secondary Ch |
1 = not reversed 2 = reversed |
Part of above 2nd channel makes one output more and the other less 1st Ch must be configured before 2nd Ch |
|
|||||
2 |
1-5 = P1-P5 |
5 = Brake or Reverse led [BR-REV] |
1 = H1 |
1 = Brake 2 = Reverse |
One H output controls brake/reverse light (eg: 2,3,5,1,1 = P3 using H1 channel for Brake) (eg: 2,4,5,1,2 = P4 using H1 channel for Reverse) Brake 'ON time' is adjustable (see [BRAKE] below) |
2 |
1-5 = P1-P5 |
6 = Left indicator led 7 = Right indicator led 8 = Flashing led (0.5s) [FLASH] |
1-18 = Activating Ch (switch/lever on a car) |
1-18 = Steering Ch (steering wheel on a car) |
1 'activating' channel controls 3 outputs |
|
|||||
Menu 3 Led, On/Off, Serial, Automation |
Pad number: | Output type: | Channel number: | Switch Action: | |
3 |
1-5 = P1-P5 |
1 = On/Off led (momentary) [MOM] |
1-18 = Channel |
Idle low (0v): 1 = Ch low 3v 2 = Ch mid 3v 3 = Ch high 3v Idle high (3v): 4 = Ch low 0v 5 = Ch mid 0v 6 = Ch high 0v |
1 channel controls 1-3 outputs 'Momentary' = non-latching (eg: 3,4,1,5,1 = P4, On only when Ch5 is low) (eg: 3,6,1,5,3 = P6, On only when Ch5 is high) |
3 |
1-5 = P1-P5 |
2 = On/Off led (latching) [LATCH-1] |
1-18 = Channel |
Start low (0v): 1 = Ch low toggle 2 = Ch high toggle Start high (3v): 3 = Ch low toggle 4 = Ch high toggle |
1 channel controls 1-2 outputs Each move toggles on/off (eg: 3,4,2,5,1 = P4, Start off, toggle when Ch5 is low) (eg: 3,6,2,5,2 = P6, Start off, toggle when Ch5 is high) |
3 |
1-5 = P1-P5 |
3 = On/Off led (latching) [LATCH-2] |
1-18 = Channel |
Channel 'high': 1 = >2s toggle 2 = <2s toggle Channel 'low': 3 = >2s toggle 4 = <2s toggle |
1 channel controls 1-4 outputs On/off based on time from center Outputs start low (0v) |
|
|||||
Directional lights |
|
|
|
|
|
3 |
1-5 = P1-P5 |
4 = Directional lights [DIR-LIGHT-1] |
1 = Front 2 = Rear |
1 = H1 (controlling motor) |
Enable any number of directional lights (other control settings below) (eg: 3,1,4,1,1 = P1, Front, H1 direction) (eg: 3,2,4,2,1 = P2, Rear, H1 direction) |
3 |
1 |
5 = Control settings [DIR-LIGHT-2] |
0 = Auto 1-18 = Channel |
Controlled with a channel: Latch (toggle) 1 = Ch low 2 = Ch high Momentary 3 = Ch high on (mid/low off) |
Common settings for all Directional lights Channel is used to switch feature on/off remotely (eg: 3,1,5,0 = Auto, always on) (eg: 3,1,5,5,1 = Switch feature on/off with Ch5) |
|
|||||
Serial |
|||||
3 |
1-5 = P1-P5 |
6 = SumPPM / CPPM [SUM] |
1 = Idle high 2 = Idle low |
1 = Normal 2 = +RSSI pulse |
RSSI pulse: 0.9-2.1ms = 0-31 signal strength |
3 | 4 = P4 only |
7 = Serial data [SERIAL] |
Baud rate: 1 = 125k 2 = 250k 3 = 500k |
1 = High byte first 2 = Low byte first |
Channel data, Volts, RSSI Pad P4 only |
|
|||||
Automation | |||||
3 |
1-5 = P1-P5 |
8 = Buffer Stop [BUFFER1] |
Time to stop: 1-6 = 1-6 seconds |
Reactivate trigger: 1-6 = 10-60s (time to 'back out') |
ONE pad can detect external trigger to control H1 Action: Slow to a stop Close throttle to rearm (manual). |
3 |
1-5 = P1-P5 |
9 = Stop & Reverse [BUFFER2] |
Time to stop: 1-6 = 1-6 seconds |
Fixed pause time: 1-6 = 4,8,15,30,45,60s Random pause time: 7 = 4-8s 8 = 8-15s 9 = 15-30s 10 = 30-45s 11 = 45-60s |
ONE pad can detect external trigger to control H1 Action: Stop-Pause-Reverse (auto). |
3 |
1-5 = P1-P5 |
10 = Station stop and continue [BUFFER3] |
Time to stop: 1-6 = 1-6 seconds |
Pause time: As above |
ONE pad can detect external trigger to control H1 Action: Stop-Pause-Continue (auto). |
|
|||||
Menu 4 Not used |
|||||
|
|||||
Menu 5 Not used |
|
||||
|
|||||
Menu 6 Infrared |
Pad number: | Output type: | Channel | Position | |
6 | 0 = IR2 address |
High digit: 0-6 = Tens (x10) (0-flash = 0) |
Low digit: 0-9 = Ones (x1) (0-flash = 0) |
||
6 |
1-5 = P1-P5 |
IR type [IR] 1 = IR1 Manual 2 = IR2 Static Addr 3 = IR3 Dynamic Addr 4 = IR4 Voltage 5 = IR4 + IR1 6 = IR4 + IR1 + IR2 7 = IR4 + IR1 + IR3 |
IR1 (Trigger channel) IR3 (Address channel) 1-18 = Channel |
IR1 (Trigger position) 1 = 'low' on 2 = 'high' on |
IR1 = Manual triggering IR2 = Continuous static address IR3 = Continuous dynamic address IR4 = Continuous battery voltage |
|
|||||
Menu 7 Other |
Item: | Options: | |||
7 |
1 = LED2 [LED2] |
1 = LED2 Disabled 2 = LED2 Enabled 3 = LED2 (not cruise control) 4 = LED2 Always on |
1-5 = P1-P5 |
Any pad driving an Led Option 3 = enabled, but not after Tx switched off |
|
7 |
2 = LVC [LVC] |
1 = LVC Disabled 2 = LVC Auto 3 = LVC Manual |
Manual threshold (volts): 2-12 = 2-12v |
Manual threshold (+tenths): 0-9 = 0.1-0.9v |
2-flash = LVC enabled, auto threshold 3-flash = LVC enabled, manual threshold |
7 |
3 = Sleep [SLEEP] |
Time before Sleep: 1-6 = 1-6 hours 7 = Never |
LVC Sleep: 1 = No 2 = Yes (5 minutes) |
Inactivity timeout (1-6 hours) LVC sleep is triggered by Low Voltage Cut (if enabled) |
|
7 |
4 = Failsafe / Cruise Control [FAIL] |
Time to stop after signal loss: 1-4 = 1-4s 5 = Sleep time |
Time to kill outputs after signal loss Use 'Sleep time' for 'cruise control' with transmitter switched off |
||
7 |
5 = Emergency Stop [STOP] |
1 = Disabled 2 = Ch 'low' stop 3 = Ch 'high' stop |
1-18 = Channel |
Time to stop: 1-6 = 1-6s |
Manual trigger over radio Quicker trigger than failsafe (eg: 7,5,2,3,6 enabled using Ch3 low with 6s decell.) |
7 |
6 = Arming [ARM] |
0 = Disabled 1-4 = Enabled using H1-H4 |
Arming based on 'off' position of one H output (eg: 7,6,1 enabled using H1) |
||
7 |
7 = Brake ON time [BR-ON] |
1-6 = 1-6s |
Brake light on after stopping | ||
7 |
8 flash = eSwitch OFF [REED] |
1-10 flash = 1-10s |
0-10 flash = Channel (0=not radio controlled) |
E-switch Time to deflect Ch to switch Rx off |
|
7 |
9 = Battery Voltage flashes [BATT-V] |
1 = Disabled 2 = Enabled on Rx led 3 = Enabled on Pad also |
Channel: 0 = Multi-1 control 1-18 = Channel |
Pad: 1-5 = P1-P5 |
Flash battery voltage (volts and tenths) On any Pad driving an Led. When Channel is made Low (eg: 7,9,3,5,1 enabled on P1 triggered with Ch5) |
7 |
10 = Led idle state [LED-HILO] |
1 = Normal 2 = Inverted |
Applies to Battery Voltage, LED2, Latch-2, Brake, Reverse, Indicators, Directional Lights Normal = OFF is Low (0v) Inverted = OFF is High (3v) (from v611-5) |
||
|
|||||
Menu 8 Selecta |
Option: | ||||
8 |
1 = Enable [SELECTA] |
Selecta Mode [S-OPTION] 1 = Disabled 2 = Selecta 3 = Selecta+TxChange |
1-18 = Channel (normally Ch2) |
Time between Rx changes [S-DELAY] 1 = Instant 2 = 0.5s 3 * 1s 4 = 1.5s 5 = 2s |
Mode 2: Selecta only: - Same Tx for all switch positions Mode 3: Selecta+TxChange: - Same or different Tx for each position |
8 |
2 = Action when deselected [S-STOP-GO] |
1 = stop 2 = continue |
'Stop' forces throttle closed 'Continue' allows throttle open or closed Throttle always closes with Tx change |
||
|
|||||
Menu 9 Reset, Bind |
|||||
9 |
1 = Not used |
||||
9 |
2 = Change variant |
Variant: 1 = Rx61-1 2 = Rx61-2 3 = Rx61-3 4 = Rx61-4 5 = Rx61-5 6 = Rx61-6 7 = Rx61-22 |
Board: 1 = Rx only |
1 = No change 2 = CHANGE (YES) |
Resets all outputs to factory settings Used to change variant |
9 |
3 = Reset (current variant) [RESET] |
1 = No reset 2 = RESET (YES) |
Resets all outputs to factory settings Does not change variant/board/bindings (eg: 9,3,2 = perform reset) |
||
|
|||||
Normal Bind |
|||||
9 |
4 = Binding |
1 * Auto 2 = DSM2 Air 3 = DSMX Air 4 = DSM2 Surface [DSMVER] |
1 * Auto Bind 2 = Manual Bind [BIND-0] |
1 * Up to 12Ch 2 = Up to 14Ch 3 = Up to 18Ch (X-Plus) [XPLUS] |
Core settings for binding Manual Bind uses pads P4 and P5 Binding is normally done with a transmitter Binding can be done with Prog4 (below) |
|
|||||
Prog4 Bind |
|||||
9 |
5 = GUID [BIND-1] |
Profile 0-15 = Tx0-Tx15 |
GUID[0] 0-255 |
GUID[1] 0-255 |
'Profile' starts with current Tx number Tx1-Tx12 match Selecta channel switch positions Tx0 and Tx13 are 'below' and 'above' Selecta positions Tx14 is used for PROG1/2/3/4 programming Tx15 is most recent 'normal bind' with a Tx |
9 |
6 = CRC [BIND-2] |
Profile 0-15 = Tx0-Tx15 |
CRC[0] 0-255 |
CRC[1] 0-255 |
|
9 |
7 = CHANNELS [BIND-3] |
Profile 0-15 = Tx0-Tx15 |
Tx Channels 3-18 = Channels |
Resolution 1 * 10bit 2 = 11bit 3 = 12bit |
DSM2 Surface = 3 channels only - (DX3/DX4S=3ch) DSM2/DSMX Air = Never less than 7 channels - (MLP4/DX4e/DX5/DX6/DX7=7ch) |
9 |
8 = PROTOCOL [BIND-4] |
Profile 0-15 = Tx0-Tx15 |
Protocol 1 * DSM2 Air 2 = DSMX Air 3 = DSM2 Surface |
||
|
|||||
Menu 10 Many-to-One Mix |
|||||
10 |
1 = Output [MMIX] |
1 = Disabled 2 = Enabled |
1-5 = P1-P5 (Output pad) |
1-18 = Number of inputs |
Only one output should be enabled Output produces a servo pulse |
10 |
2 = Inputs |
1-18 = Input 1-18 (Input number) |
1-18 = Channel number (for this input) |
Number of inputs must be set first (above) Each input can use any channel number All inputs have equal priority/effect |
|
10 |
3 = Delay |
0-9 = Overrun duration (0=none, 9=max) |
0-9 = Decay speed (0=immediate, 9=slowest) |
Stretch/hold output when inputs are reduced. Overrun/Decay settings 3s-4s max each |
|
|
|||||
Menu 11 Not used |
|||||
|
|||||
Menu 12 Multi-position channels (from v611-3) |
Multi-position channels: Multi-1 channel can control 1-36 outputs/actions Selecta channel can control 2 outputs/actions Approach 1: 12-way switch + 2 trigger buttons Switch positions can trigger direct or be 'menu' Approach 2: 1-12 pushbuttons Each position directly triggers actions Examples |
||||
12 |
1 = MULTI-1 2 = SELECTA |
1 = Setup [MULTI-0A] |
Channel: 0 = Disabled 1-18 = Channel MULTI-1 default Ch7 SELECTA default Ch2 |
Fumble time: 1 = 0.1s 2 = 0.2s 3 = 0.4s 4 * 0.8s 5 = 1.6s 6 = 3.2s |
Ch0 disables feature without changing other settings Main switch has adjustable debounce time ('fumble time') T1 and T2 buttons have fixed debounce time (0.1s after main switch settles) |
12 |
1 = MULTI-1 2 = SELECTA |
2 = Learn [MULTI-0B] Not available |
1 = Use current switch positions (no change) 2 = Learn switch positions (replace existing) |
'Learn switch positions': Default values are for a 12-way switch Any number of switch positions (1-12) Trigger buttons T1/T2 are not learned Move channel to its lowest position (1) Move up through all positions to memorise them Led flashes show learned position numbers (1-12) Switch Rx off with channel in highest (eg: 12) |
|
12 |
1-5 = P1-P5 |
3 = Switch only 4 = Switch+T1 5 = Switch+T2 [MULTI-1] |
1-12 = Switch position |
Output (momentary) 1 = Idle low 2 = Idle high Output toggle (latch) 3 = Start low 4 = Start high |
3 = switch directly controls outputs 4 = switch is 'menu' and T1 triggers 5 = switch is 'menu' and T2 triggers Any combination of switching is allowed Outputs are 'on' or 'toggled' when selected (eg: 12,1,3,7,1 = P1, switch executes at pos7, mom) (ie: while Switch is in Pos7, P1 is on) (eg: 12,3,5,8,4 = P3, T2 executes from pos8, toggle) (ie: Switch to Pos8, press T2, state of P3 toggles) |
12 |
1-5 = P1-P5 |
4 = T3 5 = T4 [MULTI-2] |
13 |
Output (momentary) 1 = Idle low 2 = Idle high Output toggle (latch) 3 = Start low 4 = Start high |
Selecta channel can control two outputs T3 channel low, T4 channel high |
|
|||||
Menu 13 Actions (from v611-3) |
Trigger |
Action |
Menu 13 assigns 'actions' to a multi-position channel This allows settings to be changed from the transmitter Actions which change settings are saved automatically Prog4 is needed to program this menu |
||
13 |
1-12 = Switch position |
3 = Switch only 4 = Switch+T1 5 = Switch+T2 [MULTI-1] |
0-255 = Action |
0-255 = Option |
Assign actions to Multi-1 channel 1 channel can control 12x3=36 actions Menu 12 defines the channel using 'Multi-1' |
13 |
13 |
4 = T3 5 = T4 [MULTI-2] |
0-255 = Action |
0-255 = Option |
Assign actions to Selecta channel Selecta channel can control two actions T3 channel low, T4 channel high |
|
Outputs on/off |
Leds External sound card |
|
Use Menu 12 |
|
|
Trigger |
0 = No action 1 = Emergency stop 2 = eSwitch off (Rx62) 3 = Battery volt display* |
0 = No option 0 0 0 |
'0' disables action/no option (eg: 13,12,2,1 = Pos12, Stop) * Battery Volt channel must be set to '0' (Menu 7) |
|
|
|
10 = Complex flash* |
1-2 = Pattern |
* Complex Flash channel must be set to '0' (Menu 5) (eg: 13,9,3,10,1 = Pos9+T1, Pattern1) (eg: 13,9,4,10,2 = Pos9+T2, Pattern2) |
|
|
Motor control |
50 = Low/Center off toggle* |
1-4 = H output |
*'Low off' assumes Direction switch is available and set correctly (Ch3) (eg: 13,3,2,50,1 = Pos3, H1) |
|
|
|
51 = Normal/Reverse toggle |
1-4 = H output |
(eg: 13,4,2,51,1 = Pos4, H1) |
|
|
|
52 = Min power- 53 = Min power+ 54 = Max power- 55 = Max power+ |
1-4 = H output 1-4 = H output 1-4 = H output 1-4 = H output |
Step size of change is 2% Press and release for each change (eg: 13,2,3,52,1 = Pos2+T1, Min-, H1) (eg: 13,2,4,53,1 = Pos2+T2, Min+, H1) |
|
|
|
56 = Inertia- 57 = Inertia+ |
1-4 = H output 1-4 = H output |
Inertia effect doubles/halves with each step (eg: 13,3,3,52,1 = Pos3+T1, Faster, H1) (eg: 13,3,4,53,1 = Pos3+T2, Slower, H1) |
3. PROGRAMMING WITH STANDARD TRANSMITTER:
|
|
|
|
|
Options are organised into menus usually relating to a type of output.
Level 1 and 2 usually select the output number (eg: 2-flash for 'P' then 4-flash for 'P4').
You select a row in the table above and make up to 5 choices, one for each level.
Invoke programming mode:
1. Switch Transmitter on.
2. Ch3 (Elevator) should be normal, not reversed.
3. Hold left/right sticks (Ch2/4) in towards middle of Tx (use rubber band if necessary).
4. Switch Receiver on and wait for the Led to flicker very fast.
5. Center all sticks.
Make choices:
6. The led flashes the setting for the first 'Level' (eg: 1-flash = Motor output 'H').
7. Yes = push the Ch3 (Elevator) stick forward (to top of Tx) to accept this option and advance to next Level.
8. No = pull the Ch3 (Elevator) stick back (to bottom of Tx) to see next option for same Level.
9. Continue through all Levels until Led comes on solid.
Settings are saved automatically at the end so switch off at any time to abort.
Say 'yes' to every item to just see what is currently set.
Changing 'P2' from Ch4 to Ch5. Level 1: 3-flash = P Level 2: 2-flash = P2 Level 3: 1-flash = Servo Level 4: 5-flash = Ch5 |
4. DX3:
1. Use full 'brake' to make receiver enter programming mode on startup.
2. Use 3-position Aux channel to make yes/no choices.