v5.0.3 Instructions for Rx41d-v5-W


PRODUCT: Rx41d-v5-W


Outputs

Outputs

Channels

Channels

1. DEFAULT SETUP

- For Train with reversable Motor.
- This receiver has full stick Ch1 throttle control enabled ('low' stick is off and has separate 'direction' channel) (video).
- This gives greater 'stroke' for easier throttle control.

Output Type
Orange wires Motor
Ch1 motor 'full stick' control (low off)
Ch3 forward/reverse 'direction' change
Red/Brown wires Battery (3-6v)
Arming/Activation: Ch1 low to enable
LVC Ch1 low to acknowledge (LVC=Low Voltage Cutoff)


2. BINDING (perform once):
1. Switch Rx on and wait ~20s until led flickers fast.
2. Switch Tx on in bind mode and Rx led should flash slowly and then go solid.
3. Change distance between Tx/Rx if binding does not work.




3. LED:
Led On = perfect reception (real-time indicator).
1 flash = Scanning (~2sec between flashes; no signal or not bound if never stops).
2 flash = LVC/Brownout (voltage went too low; check battery/motor load).

4. FAILSAFE:
The motor output is not active on startup and while scanning for a signal.
The motor output 'holds' last known settings on short signal losses (<1sec) and then cuts (>1s).

5. OTHER:
This receiver has other outputs and features that are not described.
See Rx41d-v5 for full capability.