Rx63-3 Instructions (v610)
|
|
|
|
1. DEFAULT SETUP
Item |
Setting | Details |
Purpose: |
Rx63-3 |
'Conventional' with joystick transmitter |
Red wire positive (+) Black wire negative (-) |
Battery |
3-13v Observe polarities |
H1 output Brown wires |
Motor Ch3 (Elevator) |
Integrated forward/reverse ESC for brushed motors Center off |
P1 output |
Servo Ch1 (Throttle) |
Standard servo Servo may need separate 4-6v power supply (UBEC) |
P2 output |
Servo Ch2 (Aileron) |
Standard servo Servo may need separate 4-6v power supply (UBEC) |
P3 output |
Servo Ch3 (Elevator) |
Standard servo Servo may need separate 4-6v power supply (UBEC) |
P4 output |
Servo Ch4 (Aileron) |
Standard servo Servo may need separate 4-6v power supply (UBEC) |
L input |
Auto-detect |
Monitors single cell lipo when used with a voltage booster |
Arming: |
Enabled |
Ch3 to center position (off) |
LVC | Enabled |
LVC=Low Voltage Cutoff Led 5-flash if triggered Stop and charge battery |
Inactivity Sleep | Enabled |
Invoked after 1hour Switch off and on to restart |
2. EXAMPLE CONNECTIONS:
|
|
|
|
'P' outputs are 3v when on and 0v when off. Led's need resistors to limit current to 20mA but high brightness led's allow a lower current (eg: 2-5mA). Google will reveal how to select resistor values but 220-470ohms will be safe starting values.
Servos can be powered direct from 1S lipo but 2S is normally too high. A 4 or 5v regulator is usually needed.
The 'L' pad is intended to monitor a single cell lipo when used with a voltage booster. This allows the receiver and motor to be powered with a boosted voltage and benefit from the convenience of a single lipo. The receiver will auto-detect when a lipo is connected. It will cut power to the motor when the voltage falls to 3v (LVC). The L pad is not intended for use when powering a receiver direct from a single lipo.
3. BINDING
Bind once:
1. Switch Rx on and wait ~20s until led flickers fast.
2. Switch Tx on in bind mode.
3. Rx led should flash slowly; wait for it to go solid.
Change distance between Tx/Rx if binding does not work.
4. LED:
Led On = perfect reception (real-time indicator).
1 flash = Scanning (~2sec between flashes; no signal or not bound if never stops).
5 flash = LVC/Brownout (voltage went too low; check battery/motor load).
5. FAILSAFE:
The motor output is not active on startup and while scanning for a signal.
The motor output 'holds' last known settings on short signal losses (<1sec) and then slows to a stop over 3 seconds.
6. CHANGING SETTINGS:
The following changes can be made by simply shorting two pads together (eg: with a paperclip):
1. Perform a 'Hard reset' (factory reset).
2. Change motor control between 'low off' and 'center off'.
3. Enable/disable LVC (eg: when using Nicads, NiHMs, LiFe cells).
4. Enable/disable Selecta.
5. Enable/disable Cruise Control/Failsafe.
'Paperclip' changes
This receiver has many other options that are described on the features page.
These are changed using a technique called 'programming': v610.