DT Receiver - Rx60 - Programming


PRODUCT: Rx60
INSTRUCTIONS: v6.0.1

1. PROGRAMMING APPROACH:

Settings in the Rx can be changed using a standard Tx or a special Programa device (PROG1). Both use the structure in the table below. One output or feature (ie: one row in the table) is programmed at a time. Levels 1-2 usually select the output and Levels 3-5 change its characteristics. [KEYWORDS] provide links to detailed descriptions of each feature. The 'Tx' column is for 'Tx Change' mode.


2. PROGRAMMING OPTIONS:

Level 1

Level 2
Level 3
Level 4
Level 5
Information Tx

'H'
(Motor)
Output number: Output type: Channel number: Other:  
1 flash 1 flash = H1 1 flash = Center off
(1 stick, half each way)
[M_TYPE_1]

1-10 flash = Channel 1/2 stick forward, 1/2 stick back
2
1 flash 1 flash = H1 2 flash = Low off
(2ch: power + direction)
[M_TYPE_2]

1-10 flash = Power Ch 1-10 flash = Direction Ch Low stick 0%, full stick 100%
'Direction' = forward/reverse
2
1 flash 1 flash = H1 3 flash = Servo
[M_TYPE_3]

1-10 flash = Channel Servo instead of motor
2
1 flash 1 flash = H1 4 flash = Start power
(0-100%)
[M_MIN]

0-10 flash = Tens (x10)
(0-flash = 0)
0-9 flash = Ones (x1)
(0-flash = 0)
Minimum power level
(0% for full power range)
1 flash 1 flash = H1 5 flash = Max power
(0-100%)
[M_MAX]

0-10 flash = Tens (x10)
(0-flash = 0)
0-9 flash = Ones (x1)
(0-flash = 0)
Maximum power level
(100% for full power range)
1 flash 1 flash = H1 6 flash = Motor Reverse
[M_REV]

1 flash = not reversed
2 flash = reversed

1 flash 1 flash = H1 7 flash = PWM Frequency
[M_PWM]
3 flash = 250 Hz
4 flash * 60 Hz
5 flash = 15 Hz

1 flash 1 flash = H1 8 flash = Soft start
[M_SOFT]
1 flash = 1.40s
2 flash = 0.70s
3 flash = 0.35s
4 flash = 0.18s
5 flash = 74ms
6 flash = 25ms

1=very soft
6=very fast


PADS_1
(Servo,
Brake,
Reverse,
Indicator)


Pad number: Output type: Channel number: Other:
2 flash 1-3 flash = P1-P3 1 flash = Servo (normal)
[SERVO_1]

1-10 flash = Channel 1 flash = normal speed
2-6 flash = slow motion

Servo on any pad
Full throw from full stick movement
2
2 flash 1-3 flash = P1-P 2 flash = Servo (offset)
[SERVO_2]

1-10 flash = Channel 1 flash = low/right stick
2 flash = high/left stick

Servo on any pad
Full throw from half stick movement
2
2 flash 1 flash = P1 3 flash = Servo (mixed)
2-channel mix
[SERVO_3a]

1-10 flash = Primary Ch 1 flash = 0% mix
2 flash = 12.5% mix
3 flash = 25% mix
4 flash = 50% mix
5 flash = 100% mix

P1/P2 used as a pair 2
2 flash 2 flash = P2 3 flash = Servo (mixed)
2-channel mix
[SERVO_3b]

1-10 flash = Secondary Ch 1 flash = not reversed
2 flash = reversed

P1/P2 used as a pair 2
2 flash 1-3 flash = P1-P3 4 flash = Brake or Reverse led
[BR_REV]

1-10 flash = Activating Ch
1 flash = Brake
2 flash = Reverse
1 channel controls 2 outputs
See 'Brake ON time' below [BRAKE]

2
2 flash 1-3 flash = P1-P3 5 flash = Left indicator led
6 flash = Right indicator led
7 flash = Flashing led (0.5s)

(5+6=Hazards)
[FLASH]

1-10 flash = Activating Ch
(switch/lever on a car)
1-10 flash = Steering Ch
(steering wheel on a car)
1 'activating' channel controls 3 outputs
2

PADS_2
(Led,
Logic)


Pad number: Output type: Channel number: Switch Action:
3 flash 1-3 flash = P1-P3 1 flash = On/Off
(momentary)
[MOM]

1-10 flash = Channel 1 flash = 'low' on
2 flash = 'high' on
1 channel controls 1-2 outputs
On while channel deflected
(center=both off)

2
3 flash 1-3 flash = P1-P3 2 flash = On/Off
(latching)
[LATCH_1]

1-10 flash = Channel 1 flash = 'low' on/off
2 flash = 'high' on/off
1 channel controls 1-2 outputs
Each move toggles on/off

2
3 flash 1-3 flash = P1-P3 3 flash = On/Off
(latching)
[LATCH_2]

1-10 flash = Channel 1 flash = 'high' >2s on/off
2 flash = 'high' <2s on/off
3 flash = 'low' >2s on/off
4 flash = 'low' <2s on/off

1 channel controls 1-4 outputs
On/off based on time from center
2
3 flash 2 flash = P2 4 flash = Serial
[SERIAL]


Baud rate:
1 flash = 125k
2 flash = 250k
3 flash = 500k
Channel data, Volts, RSSI
Pad P2 only
2
3 flash 1 flash = P1
5 flash = Boosted Lipo
[BOOST]


Monitor 1S lipo in voltage booster
Pad P1 only
2

OTHER

Item: Options: Pad number:
4 flash 1 flash = LED2 1 flash = LED2 Disabled
2 flash = LED2 Enabled
[LED2]

1-3 flash = LED2 Pad P1-P Any Pad number driving an Led.
Disable if all P outputs are servos
4 flash 2 flash = LVC 1 flash = LVC Disabled
2 flash = LVC Enabled
[LVC]
Low Voltage Cutoff / startup flashes
3v from <4.2v (1 flash at start)
4v from 4.3-6.0v (4 flash at start)
6v from 6.0-9.0v (2 flash at start)
9v from >9v (3 flash at start)
4 flash 3 flash = Sleep Time before Sleep:
1-6 flash = 1-6 hours
7 flash = Never
[SLEEP]

Inactivity timeout
4 flash 4 flash = Failsafe Time to stop:
1-4 flash = 1-4s
5 flash = Sleep time
[FAIL]

Time to kill outputs after signal loss
4 flash 5 flash = DSM 1 flash = Auto
2 flash = DSM2 Air
3 flash = DSMX Air
4 flash = DSM2 Surface
5 flash = DSMR Surface
[DSMVER]

1 flash = Auto Bind
2 flash = Manual Bind
[BIND]
Compatibility with transmitters
Only DSM2 supported at this time

Manual Bind uses pads P1 and P2
Connect together to enter bind mode
at startup
4 flash 6 flash = Brake ON time
1-6 flash = 1-6s
[BR_ON]

Brake light on after stopping

SELECTA
[SELECTA]

Option:
5 flash 1 flash = Options
[S_OPTION]

1 flash = Telegraph Off
2 flash = Telegraph On

3 flash = Dedicated
4 flash = Dedicated + Tx Change

Telegraph is the base option
Dedicated is a different approach
Tx Change is add-on to Dedicated

5 flash
2 flash = Activating channel
[S_ACT]

1-10 flash =
Channel to select Rx
2-12 flash =
Positions available
(eg: 3-position switch)

1-12 flash =
Position to select Rx
(eg: 1=low, 2=mid, 3=high)

Telegraph can only have 3 positions
2
5 flash
3 flash = Action when deselected
[S_STOP_GO]

1 flash = stop
2 flash = continue
'Continue' throttle may be open or closed
Servos always 'continue'
5 flash
4 flash = Tx Change channel
[S_TXCH]

1-10 flash =
Channel to change Tx

Tx Change feature 2
5 flash
5 flash = Copy profile
[S_COPY]

1 flash = Copy 1 to 2
2 flash = Copy 2 to 1

Tx Change feature

6 flash = Reset 6 flash (repeat) 1 flash = No reset
2 flash = FACTORY RESET
[RESET]


3. PROGRAMMING WITH STANDARD TRANSMITTER:


Channels

Channels

Step 3

Step 4

Steps 5-9

Options are organised into menus usually relating to a type of output.
Level 1 and 2 usually select the output number (eg: 2-flash for 'P' then 4-flash for 'P4').
You select a row in the table above and make up to 5 choices, one for each level.

Invoke programming mode:
1. Switch Transmitter on.
2. Ch3 (Elevator) should be normal, not reversed.
3. Hold left/right sticks (Ch2/4) in towards middle of Tx (use rubber band if necessary).
4. Switch Receiver on and wait for the Led to flicker very fast.
5. Center all sticks.

Make choices:
6. The led flashes the setting for the first 'Level' (eg: 1-flash = Motor output 'H').
7. Yes = push the Ch3 (Elevator) stick forward (to top of Tx) to accept this option and advance to next Level.
8. No = pull the Ch3 (Elevator) stick back (to bottom of Tx) to see next option for same Level.
9. Continue through all Levels until Led comes on solid.

Settings are saved automatically at the end so switch off at any time to abort.
Say 'yes' to every item to just see what is currently set.

Changing 'P2' from Ch4 to Ch5.
Level 1: 3-flash = P
Level 2: 2-flash = P2
Level 3: 1-flash = Servo
Level 4: 5-flash = Ch5


4. DX3:

1. Use full 'brake' to make receiver enter programming mode on startup.
2. Use 3-position Aux channel to make yes/no choices.